Loop & RCD Testers
Loop and RCD testers can work in tandem, with an RCD (Residual Current Device) capable of breaking an electrical circuit before it causes harm, whereas a Loop Tester is a quick, convenient and highly specific method of evaluating an electrical circuit for its ability to engage protective devices (circuit breakers, fuses, Ground-fault circuit interrupter).Loop testers and RCD testers are critical t...
Showing 1-20 of 43 products
RS Pro
-
Digital RCD Tester
-
-
AC
-
-
10 mA, 20 mA, 30 mA, 100 mA, 300 mA, 500mA
-
LCD
Mains
-
800g
130mm
+40°C
70mm
180mm
IRT1900
0°C
-
-
RS Pro
RSCAL
Digital RCD Tester
-
-
AC
-
-
10 mA, 20 mA, 30 mA, 100 mA, 300 mA, 500mA
-
LCD
Mains
-
800g
130mm
+40°C
70mm
180mm
IRT1900
0°C
-
-
RS Pro
UKAS
Digital RCD Tester
-
-
AC
-
-
10 mA, 20 mA, 30 mA, 100 mA, 300 mA, 500mA
-
LCD
Mains
-
800g
130mm
+40°C
70mm
180mm
IRT1900
0°C
-
-

RS Stock No.: 477-804Brand: Kewtech CorporationManufacturers Part No.: LOOPCHECK107HSN Code: 90308900
₹ 8,681.99
₹ 8,681.99 Each (Exc. GST)
Check stock
1
Megger
-
Earth Loop Impedance Tester
2 Wire
550V
-
-
±5%
-
CAT IV 300V
LCD
Battery
203 x 148 x 78mm
980g
148mm
+60°C
78mm
203mm
LT300
-10°C
CAT IV
Type G - British 3-pin
Megger
-
RCD Tester
2 Wire
300V
DC
-
-
1000mA
CAT III 300V
LCD
Battery
203 x 148 x 78mm
980g
148mm
+40°C
78mm
203mm
RCDT 320
-5°C
CAT III
Type G - British 3-pin
Megger
-
Combined Loop & RCD Tester
2 Wire
440V
AC Selective
No
±10%
4A
CAT IV 300 V, IEC 61010
LCD
Battery
203 x 148 x 78mm
1000g
148mm
+50°C
78mm
203mm
LTW425
-10°C
CAT IV
-
Megger
-
Combined Loop & RCD Tester
2 Wire
440V
AC Selective
-
±10%
4A
CAT IV 300 V, IEC 61010
LCD
Battery
203 x 148 x 78mm
1000g
148mm
+50°C
78mm
203mm
LTW325
-10°C
CAT IV
-
Megger
-
Combined Loop & RCD Tester
2 Wire
500V
AC Selective, DC Selective
Yes
±2%
10 mA, 30 mA, 100 mA, 300 mA, 500 mA, 1000mA
CAT III 300 V, IEC 61010
LCD
Battery
203 x 148 x 78mm
980g
148mm
+40°C
78mm
203mm
LRCD220
-5°C
CAT III
AS/NZS 3112, BS1363, CEE7/7
Megger
-
RCD Tester
2 Wire
300V ac
AC Selective, DC Selective
-
-
500mA
CAT III 300V
LCD
Battery
203 x 148 x 78mm
980g
148mm
+40°C
78mm
203mm
RCDT 310
-5°C
CAT III
-
Megger
-
Earth Loop Impedance Tester
2 Wire, 3 Wire
440V
AC Selective
-
±10%
4A
CAT IV 300 V, IEC 61010
LCD
Battery
78 x 203 x 148mm
1000g
148mm
+50°C
78mm
203mm
LTW315
-10°C
CAT IV
-
Megger
UKAS
Combined Loop & RCD Tester
2 Wire
500V
AC Selective, DC Selective
Yes
±2%
10 mA, 30 mA, 100 mA, 300 mA, 500 mA, 1000mA
CAT III 300 V, IEC 61010
LCD
Battery
-
980g
148mm
+40°C
78mm
203mm
LRCD220
-5°C
CAT III
-
Megger
RSCAL
Combined Loop & RCD Tester
2 Wire
500V
AC Selective, DC Selective
Yes
±2%
10 mA, 30 mA, 100 mA, 300 mA, 500 mA, 1000mA
CAT III 300 V, IEC 61010
LCD
Battery
-
980g
148mm
+40°C
78mm
203mm
LRCD220
-5°C
CAT III
-
Megger
-
Combined Loop & RCD Tester
2 Wire
500V
AC Selective, DC Selective
Yes
±2%
10 mA, 30 mA, 100 mA, 300 mA, 500 mA, 1000mA
CAT III 300 V, IEC 61010
LCD
Battery
203 x 148 x 78mm
980g
148mm
+40°C
203mm
203mm
LRCD220
-5°C
CAT III
BS 1363
Megger
RSCAL
Earth Loop Impedance Tester
2 Wire
550V
-
-
±5%
-
CAT IV 300V
LCD
Battery
-
980g
148mm
+60°C
78mm
203mm
LT300
-10°C
CAT IV
Type G - British 3-pin