Data Loggers
A data logger is a compact, battery-powered device equipped with an internal microprocessor, data storage, and one or more sensors. They can be deployed in a variety of environments to record measurements at set intervals. The devices automatically monitor and record environmental parameters over time, allowing conditions to be measured, documented, analysed and validated. The data logger conta...
Showing 1-20 of 333 products
RS Pro
1
-
PRO-USB-2
Humidity, Temperature
Humidity, Temperature, Dew Point
USB
Temperature & Humidity
-
-
-
+80 °C
-
Battery
±0.5°C
IP67
-35°C
+80°C
-
-
Yes
-
2 Years
AA
1/2AA Battery
100%RH
0.5°C
-
-
16000
-
0.5%RH
-
-
±3.5 %RH
-
RS Pro
1
-
PRO-USB-3
Voltage
Voltage
USB
Voltage
-
30V dc
-
-
-
Battery
-
-
-35°C
+80°C
-
-
Yes
-
2 Years
AA
1/2AA Battery
-
-
-
±1 %
32000
30402773
-
-
-
-
-
RS Pro
1
-
PRO-USB-1
Temperature
Temperature
USB
Temperature
-
-
-
+80 °C
-
Battery
±0.5°C
IP67
-35°C
+80°C
-
-
Yes
-
2 Years
AA
1/2AA Battery
-
0.5°C
-
-
16000
-
-
-
-
-
-
RS Pro
1
-
PRO-USB-1
Temperature
Temperature
USB
Temperature
RSCAL
-
-
+80 °C
-
Battery
±0.5°C
IP67
-35°C
+80°C
-
-
Yes
-
2 Years
AA
1/2AA Battery
-
0.5°C
-
-
16000
-
-
-
-
-
-
RS Pro
1
-
PRO-USB-1
Temperature
Temperature
USB
Temperature
UKAS
-
-
+80 °C
-
Battery
±0.5°C
IP67
-35°C
+80°C
-
-
Yes
-
2 Years
AA
1/2AA Battery
-
0.5°C
-
-
16000
-
-
-
-
-
-
RS Pro
1
-
PRO-USB-2
Humidity, Temperature
Humidity, Temperature, Dew Point
USB
Temperature & Humidity
RSCAL
-
-
+80 °C
-
Battery
±0.5°C
IP67
-35°C
+80°C
-
-
Yes
-
2 Years
AA
1/2AA Battery
100%RH
0.5°C
-
-
16000
-
0.5%RH
-
-
±3.5 %RH
-
RS Pro
1
-
PRO-USB-2
Humidity, Temperature
Humidity, Temperature, Dew Point
USB
Temperature & Humidity
UKAS
-
-
+80 °C
-
Battery
±0.5°C
IP67
-35°C
+80°C
-
-
Yes
-
2 Years
AA
1/2AA Battery
100%RH
0.5°C
-
-
16000
-
0.5%RH
-
-
±3.5 %RH
-
RS Pro
1
-
PRO-MOTE-TH
Humidity, Temperature
Humidity, Temperature, Dew Point
Wi-Fi
Temperature & Humidity
-
-
-
+80 °C
-
Battery, Mains
±0.3°C
IP67
-18°C
+55°C
-
-
Yes
-
2 Years
AA
External Temperature & Humidity Probe
100%RH
0.1°C
-
-
Unlimited
-
-
-
-
±2 RH %
-
RS Pro
2
-
PRO-MOTE-DTP+
Thermistor
Temperature
Wi-Fi
Temperature
-
-
-
+125 °C
-
Battery, Mains
±0.1°C
IP67
-18°C
+55°C
-
-
Yes
-
2 Years
AA
2x High Accuracy Thermistor Probes
-
0.01°C
-
-
Unlimited
-
-
-
-
-
-
RS Pro
1
-
PRO-MOTE-T+
Temperature
Temperature
Wi-Fi
Temperature
-
-
-
+60 °C
-
Battery, Mains
±0.2°C
IP67
-18°C
+55°C
-
-
Yes
-
2 Years
AA
Ambient High Accuracy Thermistor Probe
-
0.01°C
-
-
Unlimited
-
-
-
-
-
-
RS Pro
1
-
PRO-MOTE-TH+
Humidity, Temperature
Humidity, Temperature, Dew Point
Wi-Fi
Temperature & Humidity
-
-
-
+80 °C
-
Battery, Mains
±0.2°C
IP67
-18°C
+55°C
-
-
Yes
-
2 Years
AA
External High Accuracy Temperature & Humidity Probe
100%RH
0.01°C
-
-
Unlimited
-
-
-
-
±1.8 RH %
-
RS Pro
1
-
RS-172
-
Humidity, Temperature
-
Temperature & Humidity
-
-
-
+158 °F, +70 °C
-
Battery
±1 °C
-
-
-
-
Digital, LCD
Yes
-
3 Months
Lithium Battery
3.6 V Li-ion Battery, Clamshell, Software
100%RH
-
-
-
-
30406866
-
-
-
±3.5 %RH
-
RS Pro
1
-
RS-172TK
-
Humidity, Temperature
USB
Temperature & Humidity
-
-
-
+158 °F, +70 °C
-
Battery
±0.5 °C
-
-
-
-
LCD
Yes
-
3 Months
Lithium Battery
3.6 V Li-ion Battery, Clamshell, K-Temp Probe, Software
100%RH
-
-
-
-
-
-
-
-
±3.5 %RH
-
RS Pro
4
-
1384, 1361C
B, C, E, J, K, L, N, R, S, T, U
Temperature
USB
Temperature
-
-
-
+1112 (U) °F, +1300 (N) °C, +1370 (K) °C, +1400 (E) °F, +1600 (R/S) °C, +1652 (L) °F, +1760 (B) °C, +1760 (C) °C, +1832 (J) °F, +2372 (N) °F, +2498 (K) °F, +2912 (R/S) °F, +3200 (B) °F, +3200 (C) °F, +400 (T) °C, +600 (U) °C, +752 (T) °F, +760 (E) °C, +900 (L) °C, +999.9 (J) °C
-
Battery
±0.05 (B) %, ±0.05 (E) %, ±0.05 (J) %, ±0.05 (K) %, ±0.05 (R/S) %, ±0.1 (C) %, ±0.1 (L) %, ±0.1 (N) %, ±0.1 (T) %, ±0.1 (U) %
-
0°C
+50°C
-
LCD
Yes
-
2 days
AA
Battery, Carrying Case, Instruction Manual, Software CD, Type K Thermocouples, USB Cable
-
0.1 °F, 0.1°C
-
-
100000 (1 Input), 36000 (4 Input), 99 (Set)
-
-
-
-
-
-
RS Pro
1
-
1361C
Capacitive, Semiconductor
Humidity, Temperature
RS232
Temperature & Humidity
-
-
-
+140 °F, +60 °C
-
Battery
±0.8 °C, ±1.5 °F
-
0°C
+60°C
-
LCD
-
-
4 days
9V
Battery, Carrying Case, Data Download Software, Instruction Manual, RS232 Cable
95%RH
0.1 °C, 0.1°F
-
-
255
-
0.1%RH
-
-
±3 %RH
-
RS Pro
2
-
1365
Probe
Humidity, Temperature
RS232, USB
Temperature & Humidity
-
-
-
+140 °F, +60 °C
-
Battery
±0.5 °C, ±0.9 °F
-
0°C
+60°C
-
LCD
-
-
8 days
AAA
Battery, Instruction Manual, RS232 to USB Optical Cable & Software
95%RH
0.1 °F, 0.1°C
-
-
15000 (Continue Record), 99 (Manual)
-
0.1%RH
-
-
±3 %RH
-
...