Technical Document
Specifications
Brand
Schneider ElectricSupply Voltage
24V dc
Safety Contacts
2
Function
Safety Switch
Auxiliary Contacts
2
Range
Preventa
Safety Category ISO 13849-1
4
PL ISO 13849-1
e
SIL IEC 61508
3
Terminal Type
Screw
Width
22.5mm
Depth
114mm
Series
XPS VC
Performance Level
e
Length
99mm
Country of Origin
Germany
Product details
XY2 AU, Enabling Switch
XPS-VC switches XY2AU used in conjunction with the XPS-VC safety relay offer a certified safety solution ensuring the safety of machine operators during setting and maintenance operations
Use while carrying out adjustment of moving parts
Allows operators to enable start and stop instructions while movements are being performed at reduced speeds and in the event of immediate danger, to give an emergency stop instruction
Immediate stop (" Dead man" function) of the dangerous movement as soon as the enabling switch handle is released (this applies to machine without inertia: with immediate braking)
An emergency stop if the operator's grip tightens on the enabling switch handle
May be mounted on metal and plastic safety switches by fixing the operator key to the top of the enabling switch handle (switch stock numbers, 296-4669, 296-4675, operating key/actuator stock number 252-3870)
3 position, 2 contact positive acting switch
Safety category 4 solution in accordance with EN954-1
Ergonomic design
Approvals
BG
Standards
IEC 947-1; EN 60204-1; EN 292
Enabling Switch
Stock information temporarily unavailable.
Please check again later.
P.O.A.
1
RS Components & Controls (I) Ltd
Distribution hub - B-89, Sector 67, Noida, Gautam Budh Nagar, (Uttar Pradesh), 201 301
P.O.A.
1
Technical Document
Specifications
Brand
Schneider ElectricSupply Voltage
24V dc
Safety Contacts
2
Function
Safety Switch
Auxiliary Contacts
2
Range
Preventa
Safety Category ISO 13849-1
4
PL ISO 13849-1
e
SIL IEC 61508
3
Terminal Type
Screw
Width
22.5mm
Depth
114mm
Series
XPS VC
Performance Level
e
Length
99mm
Country of Origin
Germany
Product details
XY2 AU, Enabling Switch
XPS-VC switches XY2AU used in conjunction with the XPS-VC safety relay offer a certified safety solution ensuring the safety of machine operators during setting and maintenance operations
Use while carrying out adjustment of moving parts
Allows operators to enable start and stop instructions while movements are being performed at reduced speeds and in the event of immediate danger, to give an emergency stop instruction
Immediate stop (" Dead man" function) of the dangerous movement as soon as the enabling switch handle is released (this applies to machine without inertia: with immediate braking)
An emergency stop if the operator's grip tightens on the enabling switch handle
May be mounted on metal and plastic safety switches by fixing the operator key to the top of the enabling switch handle (switch stock numbers, 296-4669, 296-4675, operating key/actuator stock number 252-3870)
3 position, 2 contact positive acting switch
Safety category 4 solution in accordance with EN954-1
Ergonomic design
Approvals
BG
Standards
IEC 947-1; EN 60204-1; EN 292