Technical Document
Specifications
Brand
KeithleyMultimeter Type
Bench
Display Type
Digital
Model Number p
2701/E
Functions Measured
DC Current, DC Voltage, Resistance, Temperature
Absolute Maximum Resistance Measurement
120MΩ
Absolute Maximum AC Voltage Measurement
750V ac
Absolute Maximum DC Voltage Measurement
1000V dc
Absolute Maximum DC Current Measurement
3A dc
Absolute Maximum AC Current Measurement
3A ac
Absolute Maximum Temperature Measurement
+1820°C
Maximum Frequency
440Hz
DC Current Measurement Resolution
1µA dc
Resistance Measurement Resolution
1µΩ
DC Voltage Measurement Resolution
0.1µV dc
Temperature Measurement Resolution
0.001°C
Battery Type
Lithium Battery
Best Resistance Measurement Accuracy
±0.01% + 4 Digits
Dimensions
89 x 213 x 370mm
Best DC Voltage Accuracy
±0.003% + 3.5 Digits
Best Temperature Measurement Accuracy
±0.2 °C
Weight
6.5kg
Best DC Current Accuracy
±0.05% + 8 Digits
Country of Origin
China
Product details
Keithley 2700, 2701, 2750 Multimeter/Data Acquisition/Switch Systems
Keithley's Integra series systems 2700, 2701 and 2750 combine precision measurement, switching and control in a single, tightly integrated enclosure for either rack-mounted or benchtop applications. Built-in measurement functions include: DCV, ACV, DCI, ACI; Resistance, 2- or 4-wire, offset compensation selectable; Temperature (with thermocouples, RTDs or thermistors; Frequency/Period; Continuity.
Models include:
2701/E - 2 slots (RS Stock No. 760-0351)
2700/7700/E - 2 slots (RS Stock No. 760-0351)
2700/E - 2 slots (RS Stock No. 760-0357)
2750/E - 5 slots (RS Stock No. 760-0360)
Similar Features and Benefits:
Cost effective - Combines functions of digital multimeter, switch system and datalogger
True 6-digit (22 bit) resolution
Can select 12 switch/control plug-in modules
Up to 200 differential input channels (with 300 V isolation) for measurement and control
Convenient front panel inputs
ExceLINX - 1A datalogging software
Setup and Operation
These Integra systems are fully integrated measurement and control systems and are fast and easy to set up and start working within minutes of installation.
Advantages of Integrated Design
Due to their flexible modular architecture and integrated measurement, switching, and control capabilities save rack space by reducing the number of separate instruments needed.
As the number of channels grows, new test requirements evolve.
Integrated signal conditioning, scaling, stimulus, filtering and I/O capabilities eliminate the need for external circuitry when designing and building data acquisition systems.
Integra systems offer greater accuracy and repeatability to plug-in data acquisition boards, while providing faster test times than typical DMM/switch systems. This makes it possible to combine higher test yields with higher test throughput.
Different features between the models: (Please see selector guide on page 5 of the datasheet for more information)
2701
Ethernet and RS-232 interfaces – offers an Ethernet connection for high-speed and long-distance communication between a computer and various instruments. Includes 2 slots for the plug-in modules.
2700
GPIB and RS-232 interfaces
2750
GPIB and RS-232 interfaces
Dry circuit ohms (20 mV clamp) - Protects sensitive devices from damage and prevents self-heating errors during testing.
Applications include:
Production test of electronic products and devices, accelerated stress testing (AST), process monitor and control, device characterisation/R&D and low ohms, multichannel measurements.
Supplied with
LabVIEW, LabWindows/CVI, Visual Basic and C/C++ drivers (IVI style) software, manual, safety test leads
Keithley
Stock information temporarily unavailable.
Please check again later.
P.O.A.
Calibration type
No Calibration
1
RS Components & Controls (I) Ltd
Distribution hub - B-89, Sector 67, Noida, Gautam Budh Nagar, (Uttar Pradesh), 201 301
P.O.A.
Calibration type
No Calibration
1
Technical Document
Specifications
Brand
KeithleyMultimeter Type
Bench
Display Type
Digital
Model Number p
2701/E
Functions Measured
DC Current, DC Voltage, Resistance, Temperature
Absolute Maximum Resistance Measurement
120MΩ
Absolute Maximum AC Voltage Measurement
750V ac
Absolute Maximum DC Voltage Measurement
1000V dc
Absolute Maximum DC Current Measurement
3A dc
Absolute Maximum AC Current Measurement
3A ac
Absolute Maximum Temperature Measurement
+1820°C
Maximum Frequency
440Hz
DC Current Measurement Resolution
1µA dc
Resistance Measurement Resolution
1µΩ
DC Voltage Measurement Resolution
0.1µV dc
Temperature Measurement Resolution
0.001°C
Battery Type
Lithium Battery
Best Resistance Measurement Accuracy
±0.01% + 4 Digits
Dimensions
89 x 213 x 370mm
Best DC Voltage Accuracy
±0.003% + 3.5 Digits
Best Temperature Measurement Accuracy
±0.2 °C
Weight
6.5kg
Best DC Current Accuracy
±0.05% + 8 Digits
Country of Origin
China
Product details
Keithley 2700, 2701, 2750 Multimeter/Data Acquisition/Switch Systems
Keithley's Integra series systems 2700, 2701 and 2750 combine precision measurement, switching and control in a single, tightly integrated enclosure for either rack-mounted or benchtop applications. Built-in measurement functions include: DCV, ACV, DCI, ACI; Resistance, 2- or 4-wire, offset compensation selectable; Temperature (with thermocouples, RTDs or thermistors; Frequency/Period; Continuity.
Models include:
2701/E - 2 slots (RS Stock No. 760-0351)
2700/7700/E - 2 slots (RS Stock No. 760-0351)
2700/E - 2 slots (RS Stock No. 760-0357)
2750/E - 5 slots (RS Stock No. 760-0360)
Similar Features and Benefits:
Cost effective - Combines functions of digital multimeter, switch system and datalogger
True 6-digit (22 bit) resolution
Can select 12 switch/control plug-in modules
Up to 200 differential input channels (with 300 V isolation) for measurement and control
Convenient front panel inputs
ExceLINX - 1A datalogging software
Setup and Operation
These Integra systems are fully integrated measurement and control systems and are fast and easy to set up and start working within minutes of installation.
Advantages of Integrated Design
Due to their flexible modular architecture and integrated measurement, switching, and control capabilities save rack space by reducing the number of separate instruments needed.
As the number of channels grows, new test requirements evolve.
Integrated signal conditioning, scaling, stimulus, filtering and I/O capabilities eliminate the need for external circuitry when designing and building data acquisition systems.
Integra systems offer greater accuracy and repeatability to plug-in data acquisition boards, while providing faster test times than typical DMM/switch systems. This makes it possible to combine higher test yields with higher test throughput.
Different features between the models: (Please see selector guide on page 5 of the datasheet for more information)
2701
Ethernet and RS-232 interfaces – offers an Ethernet connection for high-speed and long-distance communication between a computer and various instruments. Includes 2 slots for the plug-in modules.
2700
GPIB and RS-232 interfaces
2750
GPIB and RS-232 interfaces
Dry circuit ohms (20 mV clamp) - Protects sensitive devices from damage and prevents self-heating errors during testing.
Applications include:
Production test of electronic products and devices, accelerated stress testing (AST), process monitor and control, device characterisation/R&D and low ohms, multichannel measurements.
Supplied with
LabVIEW, LabWindows/CVI, Visual Basic and C/C++ drivers (IVI style) software, manual, safety test leads