Technical Document
Specifications
Brand
HoneywellMedia Monitored
Hydrogen Gas
Device Type
Unamplified
Minimum Flow Rate
-25 sccm
Maximum Flow Rate
25 cm³/s
Supply Voltage
15 V dc
Pipe Diameter Range
0.246 in
Maximum Pressure
150psi
Material
Plastic
Minimum Operating Temperature
-40°C
Maximum Operating Temperature
+125°C
Series
AWM40000
Country of Origin
China
Product details
Amplified Airflow Sensor AWM40000 Series
The AWM40000 Series mass flow sensor family is based on proven microbridge technology and includes both amplified signal conditioned devices and unamplified sensor only devices.
When using the unamplified devices (AWM42150VH and AWM42300V), the heater control circuit and the sensing bridge supply circuit are both required for operation per specification.
These two circuits are NOT on board the sensor and must be supplied in the application. The differential amplifier circuitry is useful in providing output gain and/or introducing voltage offsets to the sensor output.
The amplified devices (AWM43300V and AWM43600V) can be used to increase output gain and introduce voltage offsets.
The differential instrumentation amplifier circuitry, heater control circuitry and sensing bridge supply circuitry are all provided onboard the amplified sensors.
Features and Benefits
Manifold mount/o-ring sealed
Ceramic flow tube (non-outgassing), 0 to 1000 sccm
High common mode pressure (150 psi ceramic flow tube only)
Operating temperature up to 125°C
High stability at null and full scale
Product Application Information
Damper control for heating, ventilation, and air conditioning systems
Gas analysers
Low vacuum control
Process control
Medical respirators and ventilators
Oxygen concentrators
Leak detection equipment
Vent hoods
Anaesthesia control
Gas metering
Gas chromatography
Stock information temporarily unavailable.
Please check again later.
P.O.A.
1
RS Components & Controls (I) Ltd
Distribution hub - B-89, Sector 67, Noida, Gautam Budh Nagar, (Uttar Pradesh), 201 301
P.O.A.
1
Technical Document
Specifications
Brand
HoneywellMedia Monitored
Hydrogen Gas
Device Type
Unamplified
Minimum Flow Rate
-25 sccm
Maximum Flow Rate
25 cm³/s
Supply Voltage
15 V dc
Pipe Diameter Range
0.246 in
Maximum Pressure
150psi
Material
Plastic
Minimum Operating Temperature
-40°C
Maximum Operating Temperature
+125°C
Series
AWM40000
Country of Origin
China
Product details
Amplified Airflow Sensor AWM40000 Series
The AWM40000 Series mass flow sensor family is based on proven microbridge technology and includes both amplified signal conditioned devices and unamplified sensor only devices.
When using the unamplified devices (AWM42150VH and AWM42300V), the heater control circuit and the sensing bridge supply circuit are both required for operation per specification.
These two circuits are NOT on board the sensor and must be supplied in the application. The differential amplifier circuitry is useful in providing output gain and/or introducing voltage offsets to the sensor output.
The amplified devices (AWM43300V and AWM43600V) can be used to increase output gain and introduce voltage offsets.
The differential instrumentation amplifier circuitry, heater control circuitry and sensing bridge supply circuitry are all provided onboard the amplified sensors.
Features and Benefits
Manifold mount/o-ring sealed
Ceramic flow tube (non-outgassing), 0 to 1000 sccm
High common mode pressure (150 psi ceramic flow tube only)
Operating temperature up to 125°C
High stability at null and full scale
Product Application Information
Damper control for heating, ventilation, and air conditioning systems
Gas analysers
Low vacuum control
Process control
Medical respirators and ventilators
Oxygen concentrators
Leak detection equipment
Vent hoods
Anaesthesia control
Gas metering
Gas chromatography