Specifications
Brand
FlukeMultimeter Type
Handheld
Model Number p
77-III
Functions Measured
AC Current, AC Voltage, DC Current, DC Voltage, Diode, Resistance
Absolute Maximum DC Current Measurement
10A dc
Absolute Maximum Resistance Measurement
32MΩ
Absolute Maximum DC Voltage Measurement
1000V dc
Absolute Maximum AC Current Measurement
10A ac
Absolute Maximum AC Voltage Measurement
1000V ac
Maximum Frequency
1kHz
DC Current Measurement Resolution
0.01mA dc
AC Current Measurement Resolution
0.01mA ac
DC Voltage Measurement Resolution
0.1mV dc
AC Voltage Measurement Resolution
1mV ac
Resistance Measurement Resolution
100mΩ
Safety Category Level
CAT II, CAT III
Maximum Operating Temperature
+50°C
Best DC Voltage Accuracy
±0.4% + 1 Digit
Dimensions
190 x 89 x 37mm
Best AC Voltage Accuracy
±2% + 2 Digits
Minimum Operating Temperature
0°C
Height
37mm
Best AC Current Accuracy
±2.5% + 2 Digits
Width
89mm
Weight
356g
Best DC Current Accuracy
±1.5% + 2 Digits
Safety Category Voltage
600 V, 1000 V
Battery Type
9V
Best Resistance Measurement Accuracy
±2% + 1 Digit
Length
190mm
Product details
Fluke 73 Series III Multimeters
All inputs, ranges and functions protected against overvoltage transients
Digital display with analogue bargraph
3200 count autoranging and manual range selection
Touch Hold® to automatically capture stable readings
Automatic power down if left unused when switched on to preserve battery life
Protective holster
Voltage, ohms, continuity and diode measurement
Voltage measurements up to 600V ac/dc with 0.1mV maximum resolution
Complies with EN61010-1 (safety standard) 600V cat II, over-voltage protection to 4KV
Supplied with
removable protective holster, TL75 test leads, 9V alkaline battery and user manual.
Stock information temporarily unavailable.
Please check again later.
P.O.A.
1
RS Components & Controls (I) Ltd
Distribution hub - B-89, Sector 67, Noida, Gautam Budh Nagar, (Uttar Pradesh), 201 301
P.O.A.
1
Technical Document
Specifications
Brand
FlukeMultimeter Type
Handheld
Model Number p
77-III
Functions Measured
AC Current, AC Voltage, DC Current, DC Voltage, Diode, Resistance
Absolute Maximum DC Current Measurement
10A dc
Absolute Maximum Resistance Measurement
32MΩ
Absolute Maximum DC Voltage Measurement
1000V dc
Absolute Maximum AC Current Measurement
10A ac
Absolute Maximum AC Voltage Measurement
1000V ac
Maximum Frequency
1kHz
DC Current Measurement Resolution
0.01mA dc
AC Current Measurement Resolution
0.01mA ac
DC Voltage Measurement Resolution
0.1mV dc
AC Voltage Measurement Resolution
1mV ac
Resistance Measurement Resolution
100mΩ
Safety Category Level
CAT II, CAT III
Maximum Operating Temperature
+50°C
Best DC Voltage Accuracy
±0.4% + 1 Digit
Dimensions
190 x 89 x 37mm
Best AC Voltage Accuracy
±2% + 2 Digits
Minimum Operating Temperature
0°C
Height
37mm
Best AC Current Accuracy
±2.5% + 2 Digits
Width
89mm
Weight
356g
Best DC Current Accuracy
±1.5% + 2 Digits
Safety Category Voltage
600 V, 1000 V
Battery Type
9V
Best Resistance Measurement Accuracy
±2% + 1 Digit
Length
190mm
Product details
Fluke 73 Series III Multimeters
All inputs, ranges and functions protected against overvoltage transients
Digital display with analogue bargraph
3200 count autoranging and manual range selection
Touch Hold® to automatically capture stable readings
Automatic power down if left unused when switched on to preserve battery life
Protective holster
Voltage, ohms, continuity and diode measurement
Voltage measurements up to 600V ac/dc with 0.1mV maximum resolution
Complies with EN61010-1 (safety standard) 600V cat II, over-voltage protection to 4KV
Supplied with