Technical Document
Specifications
Brand
Chauvin ArnouxAbsolute Maximum Temperature Measurement
+1350°C
Temperature Scale
Centigrade, Fahrenheit
Suitable for Body Measurement
No
Calibrated
RSCAL
Absolute Minimum Temperature Measurement
-40°C
Best Accuracy
±1 °C
Distance to spot Ratio
10:1
Emissivity
0.1 → 1, Adjustable
Model Number p
CA 876
Resolution
1 °C
Response Time
1 s
Length
173mm
Width
60.5mm
Height
38mm
Dimensions
173 x 60.5 x 38mm
Weight
255g
Country of Origin
Taiwan, Province Of China
Product details
C.A 876 infrared thermometer and K thermocouple
A measuring tool that meets your temperature monitoring needs.
Choice of measurement units: °C / °F.
Backlit 2000-count display.
Automatic stop.
Auto - Hold function.
Shockproof protective sheath.
Infrared measurements:
Continuous measurement capability.
Laser sight.
Stores maximum and minimum values.
K thermocouple measurements:
for emissivity adjustment and supplementary measurements.
Supplied with K thermocouple sensor (-40 °C → +200 °C).
Standards
EN61010-1 (1995-A2), protection class III Surge category (CAT III, 24 V), pollution level 2, indoor use
Stock information temporarily unavailable.
Please check again later.
₹ 60,278.32
Each (Exc. GST)
₹ 71,128.42
Each (Including GST)
1
RS Components & Controls (I) Ltd
Distribution hub - B-89, Sector 67, Noida, Gautam Budh Nagar, (Uttar Pradesh), 201 301
₹ 60,278.32
Each (Exc. GST)
₹ 71,128.42
Each (Including GST)
1
Technical Document
Specifications
Brand
Chauvin ArnouxAbsolute Maximum Temperature Measurement
+1350°C
Temperature Scale
Centigrade, Fahrenheit
Suitable for Body Measurement
No
Calibrated
RSCAL
Absolute Minimum Temperature Measurement
-40°C
Best Accuracy
±1 °C
Distance to spot Ratio
10:1
Emissivity
0.1 → 1, Adjustable
Model Number p
CA 876
Resolution
1 °C
Response Time
1 s
Length
173mm
Width
60.5mm
Height
38mm
Dimensions
173 x 60.5 x 38mm
Weight
255g
Country of Origin
Taiwan, Province Of China
Product details
C.A 876 infrared thermometer and K thermocouple
A measuring tool that meets your temperature monitoring needs.
Choice of measurement units: °C / °F.
Backlit 2000-count display.
Automatic stop.
Auto - Hold function.
Shockproof protective sheath.
Infrared measurements:
Continuous measurement capability.
Laser sight.
Stores maximum and minimum values.
K thermocouple measurements:
for emissivity adjustment and supplementary measurements.
Supplied with K thermocouple sensor (-40 °C → +200 °C).
Standards
EN61010-1 (1995-A2), protection class III Surge category (CAT III, 24 V), pollution level 2, indoor use