ABB Current Monitoring Relay, DPDT

RS Stock No.: 465-274Brand: ABBManufacturers Part No.: CM-SRS.M2
brand-logo
View all in Monitoring Relays

Technical Document

Specifications

Brand

ABB

Monitoring Application

Current

Contact Configuration

DPDT

Minimum Current Sensed

0.3A

Maximum Current Sensed

15A

Current Sensitivity

Overcurrent, Undercurrent

Time Delay

0 s, 0.1 → 30s

Height

78mm

Length

100mm

Operating Temperature Range

-20 → +60°C

Minimum Operating Temperature

-20°C

Width

22.5mm

Maximum Operating Temperature

+60°C

Dimensions

100 x 22.5 x 78mm

Current Range

0.3 → 1.5 A, 1 → 5 A, 3 → 15A

Product details

CM-SRS.M MultiFunction Current Monitoring - Single Phase AC/DC

Depending on the configuration, the current monitoring relays CM-SRS.M can be used for over or undercurrent monitoring in single-phase AC and/or DC systems. The current to be monitored (measured value) is applied to terminals B1/B2/B3-C. Open or closed-circuit principle are configurable.

Monitoring of DC- and AC-currents: CM-SRS.M1: 3mA-1 A and CM-SRS.M2: 0.3-15A
RMS measuring principle
One device includes 3 measuring ranges
Over- and undercurrent monitoring configurable
Open- or closed circuit principle configurable
Latching function configurable
Hysteresis adjustable from 3-30%
Start-up delay TS adjustable 0; 0.1-30s
Tripping delay TV adjustable 0; 0.1-30s
2 c/o contacts
22.5mm width
3 LED's for status indication

You may be interested in
Stock information temporarily unavailable.

P.O.A.

ABB Current Monitoring Relay, DPDT
Imported by:

RS Components & Controls (I) Ltd

Distribution hub - B-89, Sector 67, Noida, Gautam Budh Nagar, (Uttar Pradesh), 201 301

P.O.A.

ABB Current Monitoring Relay, DPDT
Stock information temporarily unavailable.

Stock information temporarily unavailable.

Please check again later.

You may be interested in

Technical Document

Specifications

Brand

ABB

Monitoring Application

Current

Contact Configuration

DPDT

Minimum Current Sensed

0.3A

Maximum Current Sensed

15A

Current Sensitivity

Overcurrent, Undercurrent

Time Delay

0 s, 0.1 → 30s

Height

78mm

Length

100mm

Operating Temperature Range

-20 → +60°C

Minimum Operating Temperature

-20°C

Width

22.5mm

Maximum Operating Temperature

+60°C

Dimensions

100 x 22.5 x 78mm

Current Range

0.3 → 1.5 A, 1 → 5 A, 3 → 15A

Product details

CM-SRS.M MultiFunction Current Monitoring - Single Phase AC/DC

Depending on the configuration, the current monitoring relays CM-SRS.M can be used for over or undercurrent monitoring in single-phase AC and/or DC systems. The current to be monitored (measured value) is applied to terminals B1/B2/B3-C. Open or closed-circuit principle are configurable.

Monitoring of DC- and AC-currents: CM-SRS.M1: 3mA-1 A and CM-SRS.M2: 0.3-15A
RMS measuring principle
One device includes 3 measuring ranges
Over- and undercurrent monitoring configurable
Open- or closed circuit principle configurable
Latching function configurable
Hysteresis adjustable from 3-30%
Start-up delay TS adjustable 0; 0.1-30s
Tripping delay TV adjustable 0; 0.1-30s
2 c/o contacts
22.5mm width
3 LED's for status indication