ABB Voltage Monitoring Relay, 1 Phase, DPDT, 3→30 V, 6→60 V, 30→300 V, 60→600 V, DIN Rail

RS Stock No.: 775-7955Brand: ABBManufacturers Part No.: 1SVR730830R0400 CM-ESS.2S
brand-logo
View all in Monitoring Relays

Technical Document

Specifications

Brand

ABB

Monitoring Application

Voltage

Electrical Phase

1

Contact Configuration

DPDT

Voltage Sensing Range

3→30 V, 6→60 V, 30→300 V, 60→600 V

Voltage Sensitivity

Overvoltage, Undervoltage

Mounting Type

DIN Rail

Minimum Current Sensed

10mA

Time Delay

0 s, 0.1 → 30s

Frequency Sensing Range

50 → 60Hz

Series

CM-ESS

Maximum Voltage Sensed

30 V, 60 V, 300 V, 600V

Height

85.6mm

Length

103.7mm

Minimum Voltage Sensed

3 V (Volts), 6 V (Volts), 30 V (Volts), 60 V (Volts)

Operating Temperature Range

+60°C

Terminal Type

Screw

Standards Met

IEC

Minimum Operating Temperature

-20°C

Width

22.5mm

Maximum Operating Temperature

+60°C

Dimensions

103.7 x 22.5 x 85.6mm

Current Range

2 → 4A

Country of Origin

Germany

Product details

CM-ESS Voltage Monitoring Relay - Single Phase AC/DC

Depending on the configuration, the voltage monitoring relays CM-ESS.1 and CM-ESS.2 can be used for over- or undervoltage monitoring in single-phase AC and/or DC systems. The voltage to be monitored (measured value) is applied to terminals B-C. The devices work according the open-circuit principle.

If the measured value exceeds resp. drops below the adjusted threshold value, the output relay(s) energize(s): on the CM-ESS.1 immediately, on the CM-ESS.2 after the set tripping delay TV. If the measured value exceeds resp. drops below the threshold value plus resp. minus the adjusted hysteresis, the output relay(s) de-energize(s).

Monitoring of DC- and AC-voltages from 3-600V
RMS measuring principle
One device includes 4 measuring ranges: 3-30V, 6-60V, 30-300V, 60-600V
Over- and undervoltage monitoring configurable
Hysteresis adjustable from 3-30%
Tripping delay TV adjustable 0; 0.1-30s
3 supply voltage versions
2 c/o contacts
22.5mm width
3 LED's for status indication

Stock information temporarily unavailable.

Please check again later.

Stock information temporarily unavailable.

₹ 25,295.05

Each (Exc. GST)

₹ 29,848.16

Each (inc. GST)

ABB Voltage Monitoring Relay, 1 Phase, DPDT, 3→30 V, 6→60 V, 30→300 V, 60→600 V, DIN Rail
Imported by:

RS Components & Controls (I) Ltd

Distribution hub - B-89, Sector 67, Noida, Gautam Budh Nagar, (Uttar Pradesh), 201 301

₹ 25,295.05

Each (Exc. GST)

₹ 29,848.16

Each (inc. GST)

ABB Voltage Monitoring Relay, 1 Phase, DPDT, 3→30 V, 6→60 V, 30→300 V, 60→600 V, DIN Rail
Stock information temporarily unavailable.

Buy in bulk

quantityUnit price
1 - 4₹ 25,295.05
5 - 9₹ 24,031.21
10 - 24₹ 22,764.77
25 - 49₹ 21,500.93
50+₹ 20,235.78

Technical Document

Specifications

Brand

ABB

Monitoring Application

Voltage

Electrical Phase

1

Contact Configuration

DPDT

Voltage Sensing Range

3→30 V, 6→60 V, 30→300 V, 60→600 V

Voltage Sensitivity

Overvoltage, Undervoltage

Mounting Type

DIN Rail

Minimum Current Sensed

10mA

Time Delay

0 s, 0.1 → 30s

Frequency Sensing Range

50 → 60Hz

Series

CM-ESS

Maximum Voltage Sensed

30 V, 60 V, 300 V, 600V

Height

85.6mm

Length

103.7mm

Minimum Voltage Sensed

3 V (Volts), 6 V (Volts), 30 V (Volts), 60 V (Volts)

Operating Temperature Range

+60°C

Terminal Type

Screw

Standards Met

IEC

Minimum Operating Temperature

-20°C

Width

22.5mm

Maximum Operating Temperature

+60°C

Dimensions

103.7 x 22.5 x 85.6mm

Current Range

2 → 4A

Country of Origin

Germany

Product details

CM-ESS Voltage Monitoring Relay - Single Phase AC/DC

Depending on the configuration, the voltage monitoring relays CM-ESS.1 and CM-ESS.2 can be used for over- or undervoltage monitoring in single-phase AC and/or DC systems. The voltage to be monitored (measured value) is applied to terminals B-C. The devices work according the open-circuit principle.

If the measured value exceeds resp. drops below the adjusted threshold value, the output relay(s) energize(s): on the CM-ESS.1 immediately, on the CM-ESS.2 after the set tripping delay TV. If the measured value exceeds resp. drops below the threshold value plus resp. minus the adjusted hysteresis, the output relay(s) de-energize(s).

Monitoring of DC- and AC-voltages from 3-600V
RMS measuring principle
One device includes 4 measuring ranges: 3-30V, 6-60V, 30-300V, 60-600V
Over- and undervoltage monitoring configurable
Hysteresis adjustable from 3-30%
Tripping delay TV adjustable 0; 0.1-30s
3 supply voltage versions
2 c/o contacts
22.5mm width
3 LED's for status indication