Technical Document
Specifications
Brand
FlukeAbsolute Maximum AC Current Measurement
2000A ac
Absolute Maximum DC Current Measurement
2000A dc
Absolute Maximum AC Voltage Measurement
600V ac
Absolute Maximum DC Voltage Measurement
1000V dc
Absolute Maximum Resistance Measurement
400kΩ
Model Number
355
Calibrated
UKAS
AC Current Measurement Resolution
10mA
DC Current Measurement Resolution
10mA
Best DC Current Accuracy
±1.5% +15 Digits
Clamp Meter Type
AC/DC Clamp Meter
Best AC Current Accuracy
±3.5% +5 digits
Best AC Voltage Accuracy
±3% +5 Digits
Jaw Capacity Busbars
58mm
True RMS
Yes
Best DC Voltage Accuracy
±1% +10 Digits
Functions Measured
AC Current, AC Voltage, Continuity, DC Current, DC Voltage, Frequency, Resistance
Maximum Conductor Size
58mm
Maximum Operating Temperature
+50°C
Width
98mm
DC Current Measurement Range
40/400/2000/1400 A
Dimensions
300 x 98 x 52mm
Minimum Operating Temperature
0°C
Height
52mm
AC Voltage Measurement Resolution
1mV
AC Current Measurement Range
40 A, 400 A, 2000 A, 1400 A
Battery Life
100 h
Weight
814g
Safety Category Level
CAT IV, CAT III
Safety Category Voltage
600 V, 1000V
Battery Type
AA
Safety Category
CAT III 1000 V, CAT IV 600V
Best Resistance Measurement Accuracy
±1.5% +5 Digits
Display Type
LCD
Power Source
Battery
Length
300mm
Resistance Measurement Resolution
100mΩ
DC Voltage Measurement Resolution
1mV
AC Voltage Measurement Range
4 V, 40 V, 400 V, 600 V
Country of Origin
China
Product details
Fluke 355 True-RMS, 2000A AC/DC
Confidently take reliable readings with the True-rms, Fluke 355 digital clamp meter; the tool of choice for high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements.
Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians.
4000 count backlit display
True-RMS AC + DC current & voltage measurement
True RMS crest factor = 2.4
Motor inrush current measurement
Min/Max/Average recording mode
Frequency Measurement
Voltage AC/DC
Resistance measurement
Continuity measurement with beeper
58mm dia conductor jaw capacity
Safety to EN61010 CAT IV 600 V, CAT III 1000 V
Supplied with
C43 soft case, 6 AA alkaline batteries, TL224 1.5m silicone test leads, TP2 slim reach probes (2 mm), AC285 crocodile clips and users manual
Stock information temporarily unavailable.
Please check again later.
P.O.A.
Calibration type
UKAS Calibration
1
RS Components & Controls (I) Ltd
Distribution hub - B-89, Sector 67, Noida, Gautam Budh Nagar, (Uttar Pradesh), 201 301
P.O.A.
Calibration type
UKAS Calibration
1
Technical Document
Specifications
Brand
FlukeAbsolute Maximum AC Current Measurement
2000A ac
Absolute Maximum DC Current Measurement
2000A dc
Absolute Maximum AC Voltage Measurement
600V ac
Absolute Maximum DC Voltage Measurement
1000V dc
Absolute Maximum Resistance Measurement
400kΩ
Model Number
355
Calibrated
UKAS
AC Current Measurement Resolution
10mA
DC Current Measurement Resolution
10mA
Best DC Current Accuracy
±1.5% +15 Digits
Clamp Meter Type
AC/DC Clamp Meter
Best AC Current Accuracy
±3.5% +5 digits
Best AC Voltage Accuracy
±3% +5 Digits
Jaw Capacity Busbars
58mm
True RMS
Yes
Best DC Voltage Accuracy
±1% +10 Digits
Functions Measured
AC Current, AC Voltage, Continuity, DC Current, DC Voltage, Frequency, Resistance
Maximum Conductor Size
58mm
Maximum Operating Temperature
+50°C
Width
98mm
DC Current Measurement Range
40/400/2000/1400 A
Dimensions
300 x 98 x 52mm
Minimum Operating Temperature
0°C
Height
52mm
AC Voltage Measurement Resolution
1mV
AC Current Measurement Range
40 A, 400 A, 2000 A, 1400 A
Battery Life
100 h
Weight
814g
Safety Category Level
CAT IV, CAT III
Safety Category Voltage
600 V, 1000V
Battery Type
AA
Safety Category
CAT III 1000 V, CAT IV 600V
Best Resistance Measurement Accuracy
±1.5% +5 Digits
Display Type
LCD
Power Source
Battery
Length
300mm
Resistance Measurement Resolution
100mΩ
DC Voltage Measurement Resolution
1mV
AC Voltage Measurement Range
4 V, 40 V, 400 V, 600 V
Country of Origin
China
Product details
Fluke 355 True-RMS, 2000A AC/DC
Confidently take reliable readings with the True-rms, Fluke 355 digital clamp meter; the tool of choice for high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements.
Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians.
4000 count backlit display
True-RMS AC + DC current & voltage measurement
True RMS crest factor = 2.4
Motor inrush current measurement
Min/Max/Average recording mode
Frequency Measurement
Voltage AC/DC
Resistance measurement
Continuity measurement with beeper
58mm dia conductor jaw capacity
Safety to EN61010 CAT IV 600 V, CAT III 1000 V
Supplied with
C43 soft case, 6 AA alkaline batteries, TL224 1.5m silicone test leads, TP2 slim reach probes (2 mm), AC285 crocodile clips and users manual