Technical Document
Specifications
Brand
FlukeLoop Impedance Test Type
Phase to Earth, Phase to Neutral
Calibrated
RSCAL
Automatic RCD Test
Yes
RCD Ramp Test
Yes
Model Number p
1664FC
Insulation Test Voltage
50 V, 100 V, 250 V, 500 V, 1000 V
Maximum Voltage Measurement
500V ac/dc
Test Type
Continuity, Frequency, Insulation Resistance, Loop and Line Resistance, Measure Motor Windings, Phase Sequence Test, Prospective Earth Fault Current, Prospective Short Circuit Current, RCD Test, Resistance, Voltage, Wiring Polarity
Earth Resistance Measurement
Yes
Downloadable Data
Yes
Interface Type
BLE, USB
Continuity Test Current
10mA
RCD Test Type
A/F, AC, B/B+, G, S
Remote Switch Mode
Yes
IP Rating
IP40
Safety Category Level
CAT III, CAT IV
Plug Type
UK
Maximum Continuity Resistance
2000Ω
Safety Category Voltage
300 V, 500 V
Battery Type
AA
Dimensions
100 x 250 x 125mm
Safety Category
CAT III 500 V, CAT IV 300 V
Minimum Continuity Resistance
20Ω
Power Source
Battery
Height
125mm
Width
250mm
Length
100mm
Weight
1.3 (with Battery)kg
Country of Origin
United Kingdom
Product details
Fluke 1664 FC Multifunction Installation Testers
Fluke 1664 part of the 1660 Series. The new Fluke 1660 series verify the safety of electrical installations in domestic, commercial and industrial applications. They ensure that fixed wiring is safe and correctly installed to meet the requirements of IEC 60364 and all relevant local standards. Fluke 1660 series are the only testers that help prevent damage to connected appliances.
Fluke 1664 FC contains the Insulation-PreTest™ safety function (patent pending). This function prevents you from performing tests with appliances that are connected to the system during test, eliminating accidental damage.
With the addition of Fluke Connect, you can now send test results directly to your smartphone. The results can then be transmitted to other members of the team. Data can also be saved to Fluke Cloud™ Storage, reducing the amount of paperwork and possible errors. It is a secure and accurate way to store test data and create test certificates with Fluke DMS (data management software).
Features
Insulation-PreTest™ safety function
Insulation at L-N, N-PE inputs
Automatic test sequence
Continuity at L-N, N-PE inputs
Fluke Connect® compatibility
ShareLive™ Calling
FlukeCloud™ Storage
On/Off switchable auto-start for RCD and looptest
Z max memory
Heavy duty, single input line cord
Supplied with
The Fluke 1664 FC comes with 6 x AA (LR6) cell batteries, CI600 hard carrying case, zero adapter, heavy-duty mains cord, test lead set, padded carrying/waist strap, quick reference guide, TP165X remote control probe & lead set (FTP used probes - UK only) and User's manual on CD-ROM.
Standards
IEC 60364
Stock information temporarily unavailable.
Please check again later.
P.O.A.
1
RS Components & Controls (I) Ltd
Distribution hub - B-89, Sector 67, Noida, Gautam Budh Nagar, (Uttar Pradesh), 201 301
P.O.A.
1
Technical Document
Specifications
Brand
FlukeLoop Impedance Test Type
Phase to Earth, Phase to Neutral
Calibrated
RSCAL
Automatic RCD Test
Yes
RCD Ramp Test
Yes
Model Number p
1664FC
Insulation Test Voltage
50 V, 100 V, 250 V, 500 V, 1000 V
Maximum Voltage Measurement
500V ac/dc
Test Type
Continuity, Frequency, Insulation Resistance, Loop and Line Resistance, Measure Motor Windings, Phase Sequence Test, Prospective Earth Fault Current, Prospective Short Circuit Current, RCD Test, Resistance, Voltage, Wiring Polarity
Earth Resistance Measurement
Yes
Downloadable Data
Yes
Interface Type
BLE, USB
Continuity Test Current
10mA
RCD Test Type
A/F, AC, B/B+, G, S
Remote Switch Mode
Yes
IP Rating
IP40
Safety Category Level
CAT III, CAT IV
Plug Type
UK
Maximum Continuity Resistance
2000Ω
Safety Category Voltage
300 V, 500 V
Battery Type
AA
Dimensions
100 x 250 x 125mm
Safety Category
CAT III 500 V, CAT IV 300 V
Minimum Continuity Resistance
20Ω
Power Source
Battery
Height
125mm
Width
250mm
Length
100mm
Weight
1.3 (with Battery)kg
Country of Origin
United Kingdom
Product details
Fluke 1664 FC Multifunction Installation Testers
Fluke 1664 part of the 1660 Series. The new Fluke 1660 series verify the safety of electrical installations in domestic, commercial and industrial applications. They ensure that fixed wiring is safe and correctly installed to meet the requirements of IEC 60364 and all relevant local standards. Fluke 1660 series are the only testers that help prevent damage to connected appliances.
Fluke 1664 FC contains the Insulation-PreTest™ safety function (patent pending). This function prevents you from performing tests with appliances that are connected to the system during test, eliminating accidental damage.
With the addition of Fluke Connect, you can now send test results directly to your smartphone. The results can then be transmitted to other members of the team. Data can also be saved to Fluke Cloud™ Storage, reducing the amount of paperwork and possible errors. It is a secure and accurate way to store test data and create test certificates with Fluke DMS (data management software).
Features
Insulation-PreTest™ safety function
Insulation at L-N, N-PE inputs
Automatic test sequence
Continuity at L-N, N-PE inputs
Fluke Connect® compatibility
ShareLive™ Calling
FlukeCloud™ Storage
On/Off switchable auto-start for RCD and looptest
Z max memory
Heavy duty, single input line cord
Supplied with
The Fluke 1664 FC comes with 6 x AA (LR6) cell batteries, CI600 hard carrying case, zero adapter, heavy-duty mains cord, test lead set, padded carrying/waist strap, quick reference guide, TP165X remote control probe & lead set (FTP used probes - UK only) and User's manual on CD-ROM.
Standards
IEC 60364