Technical Document
Specifications
Brand
SMCMaximum Operating Pressure
8bar
Pressure Type
Positive Pressure
Connection
Rc 1/4
Suitable Media
Air, Gas
Voltage Rating
125 V ac, 125 V dc, 250 V ac, 30V dc
Connection Thread Size
1/4 in
Manufacturer Series
IS3000
Contact Operation
Normally Closed, Normally Open
Connection Thread Standard
Rc
Minimum Operating Temperature
-5°C
Maximum Operating Temperature
+60°C
Country of Origin
France
Product details
IS 3000 series pressure switches
Adjustment of pressure by screw and adjustment protection by nut.
High operating frequency: 1 operation per second.
Service life greater than 10 million cycles.
Relay output 1 N/O-N/C.
Pressure Switches
Warning
Compressed air whilst generally considered a safe source of energy must always be treated with caution and under no circumstances be used for any other purposes than that for which it is intended.
₹ 10,489.71
₹ 10,489.71 Each (Exc. GST)
₹ 12,377.86
₹ 12,377.86 Each (inc. GST)
1
RS Components & Controls (I) Ltd
Distribution hub - B-89, Sector 67, Noida, Gautam Budh Nagar, (Uttar Pradesh), 201 301
₹ 10,489.71
₹ 10,489.71 Each (Exc. GST)
₹ 12,377.86
₹ 12,377.86 Each (inc. GST)
1
Stock information temporarily unavailable.
Please check again later.
quantity | Unit price |
---|---|
1 - 4 | ₹ 10,489.71 |
5+ | ₹ 9,882.02 |
Technical Document
Specifications
Brand
SMCMaximum Operating Pressure
8bar
Pressure Type
Positive Pressure
Connection
Rc 1/4
Suitable Media
Air, Gas
Voltage Rating
125 V ac, 125 V dc, 250 V ac, 30V dc
Connection Thread Size
1/4 in
Manufacturer Series
IS3000
Contact Operation
Normally Closed, Normally Open
Connection Thread Standard
Rc
Minimum Operating Temperature
-5°C
Maximum Operating Temperature
+60°C
Country of Origin
France
Product details
IS 3000 series pressure switches
Adjustment of pressure by screw and adjustment protection by nut.
High operating frequency: 1 operation per second.
Service life greater than 10 million cycles.
Relay output 1 N/O-N/C.
Pressure Switches
Warning
Compressed air whilst generally considered a safe source of energy must always be treated with caution and under no circumstances be used for any other purposes than that for which it is intended.